01 / CIRCUIT BOUNDARIES AND LUBRICATION FUNCTIONS
Circuit boundaries and lubrication functions
A useful starting model is a circulating service loop linking the sump tank, pumps, cooler and temperature control, full flow filtration and engine consumers, with oil returning to the sump. The separate cleaning circuit treats oil drawn from the tank. Figure 1 distinguishes these functions without reproducing a ship installation drawing. [2]
The DMS ID20 screen shows the main oil service alongside cylinder oil and hydraulic control oil arrangements. Its main service includes two pumps, a cooler, filtration and labelled branches to bearings and pistons. Sharing a screen does not make these services interchangeable. Each connection needs to be traced before assigning a measured response to a particular circuit. [5]
ID21 identifies a separate stern tube system. ID22 covers transfer connections, while ID27 includes waste oil, sludge and engine drain routes. Transfer and drain lines require their own boundaries; the diagram must not imply that all drained oil returns as clean system oil. [5]
Examine the authentic main oil service screenEnlarge image
Figure 2. ID20 Main LO Service System, simulator time 00:00:10. DMS-2024A-2D V1.0, VLCC with MAN B&W 7S80ME. Supplied by Nikolaos Diakakis on 28 October 2026. [5]
02 / OIL CIRCULATION AND COOLING
Oil circulation and cooling
The ID20 main oil cooler has cooling water connections marked 31, providing a direct point of comparison with the LT fresh water system. Oil temperature affects viscosity, so cooling and delivery must be assessed together. Supply pressure alone does not measure the oil film in a bearing; local load, speed, geometry and lubricant properties also matter.
A measurement plan should identify pump status, engine inlet pressure, oil temperatures around the cooler, LT inlet and outlet conditions, filter differential pressure and controller mode. Record each sensor location and confirm its units. A warmer LT inlet is a different observation from a restricted oil filter, although both may influence the service response. Temperature differences describe thermal behaviour; calculating heat transfer additionally requires valid flow and fluid property data. A single temperature difference cannot establish cooler performance or prove fouling.
Filter differential pressure also depends on flow and oil viscosity, so an increase cannot be assigned to contamination without comparable conditions. [6] An automatic cleaning event, where supported, should be logged with its timing and the corresponding pressures. Likewise, a control valve may alter cooler bypass flow while maintaining delivery temperature. The planned comparison should retain controller mode and valve indication so that temperature stability is not mistaken for unchanged cooling conditions.
03 / FILTRATION AND OIL CONDITION
Filtration and oil condition
Full flow filtration protects the engine supply by retaining particles within the filter's capabilities. Centrifugal separation in a separate cleaning circuit addresses water and separable contaminants. These complementary processes do not restore every degraded oil property. ID24 depicts the separator, feed pump, heater and associated controls, with connections marked 23. Its complete tank routing needs confirmation through that interface. [3, 5]
Condition monitoring adds evidence beyond hydraulic and thermal readings. Laboratory trends should retain sample location, oil identity, date and operating hours, and interpret several properties together. Relevant observations include viscosity, water and insolubles. Limits must come from the applicable engine and lubricant guidance. WinGD's analysis methodology provides a reference, but its engine specific numerical limits are not transferred to this MAN B&W simulator model. Any claim that DMS models contamination or oil degradation requires separate confirmation. [4]
Examine the authentic purifier screenEnlarge image
Figure 3. ID24 No.1 LO Purifier, simulator time 00:01:27. Source and model as Figure 2. ID23 labels identify circuit connections to be traced. The panel does not demonstrate an active purification run. [5]
04 / PROPOSED INVESTIGATION AND SIMULATOR EVIDENCE
Proposed investigation and simulator evidence
The supplied screens establish layout and snapshot indications. Numerous zero flow readings, and the inactive purifier panel, prevent their use as evidence of a loaded reference run. The displayed 45.0 and 90.00 controller fields are recorded settings, not validated operating limits. The DMS 2017 manual also mixes fuel instructions into section 2.7.1; circuit identification must therefore be checked against the installed version. [1, 5]
We propose first establishing a stable reference at a documented engine load. Record initial tank levels, pump selection, valve configuration and control mode. Confirm available measurements, logging intervals, supported disturbances and stopping criteria before changing the model. Then apply one confirmed cooling disturbance, such as a change in LT inlet conditions if the installed model supports it, while keeping other initial conditions comparable.
Compare synchronised trends before, during and after the disturbance. Record oil delivery pressure, temperatures, available flow, filter differential pressure and control response. A higher oil delivery temperature accompanying a warmer LT inlet would support a reduced cooling margin hypothesis, without identifying the cause of every pressure change. Compare alternative explanations, including changed circulation, valve response or measurement location. Restore the reference, document interventions and repeat only after confirming comparable starting conditions. Report unavailable measurements and unresolved hypotheses alongside any measured outcome.
05 / TECHNICAL COLLABORATION
Technical collaboration
We invite marine engineers, maritime institutions and simulator developers to review the circuit map and measurement plan with us. A joint pilot would agree the technical question, model boundaries, responsibilities, permission to use data and reporting format before trials. Its deliverable would be a documented comparison of observations, interpretations and remaining uncertainty, supporting further work on simulator based engineering investigation.
TECHNICAL TERMINOLOGY
Terms used in this study
LO means lubricating oil; LT means low temperature. “Purifier” follows the DMS screen label. “Centrifugal separator” names the separation equipment without inferring a verified operating configuration. Supply pressure and filter differential pressure refer to different measurements.
- System oil
- Λάδι συστήματος
- Cylinder oil
- Κυλινδρέλαιο
- Hydraulic control oil
- Υδραυλικό λάδι ελέγχου
- Oil sump tank
- Δεξαμενή συλλογής λιπαντικού
- Lubricating oil cooler
- Ψυγείο λιπαντικού ελαίου
- Full flow filter
- Φίλτρο πλήρους ροής
- Centrifugal separator
- Φυγοκεντρικός διαχωριστήρας
- Oil purifier
- Καθαριστής λιπαντικού ελαίου
- Backflushing
- Αντίστροφη πλύση
- Differential pressure
- Διαφορική πίεση
- Oil film
- Λιπαντικό υμένιο
- Oil condition monitoring
- Παρακολούθηση κατάστασης λιπαντικού
- Stern tube lubrication
- Λίπανση χοάνης ελικοφόρου άξονα
- Reference condition
- Κατάσταση αναφοράς
- Heat rejection
- Απαγωγή θερμότητας
- Insolubles
- Αδιάλυτα συστατικά
REFERENCES
Sources and documentation
- [1]
DMS 2017. Marine Engine Room Simulator Manual. Cover date 30 November 2024. Section 2.7.1 ID20, printed pp. 30–31, document pp. 59–60. Supplied reference manual; screen version differs.
- [2]
Everllence. Efficiency improvements Main engine auxiliary systems. 5510-0201-02, June 2026. Section 5, pp. 31 and 33, Figures 20 and 22. General circuit reference; numerical examples concern a different engine.
Read the technical reference - [3]
Alfa Laval. Lube oil treatment. Reference for filtration and separate separator cleaning.
Read the technical reference - [4]
WinGD. Lubricants. DTAA001621, Revision B, 25 November 2025. Sections 3.2–3.4, printed pp. 16–19. Oil analysis methodology only.
Read the technical reference - [5]
Diakakis, N. Five authentic DMS-2024A-2D V1.0 screens supplied on 28 October 2026. ID20 Main LO Service System 00:00:10; ID21 SternTube LO System 00:00:24; ID22 LO Transfer System 00:00:54; ID27 Lubricate Oil Drain System 00:01:08; ID24 No.1 LO Purifier 00:01:27. Times are simulator clock readings. Figures 2 and 3 reproduce the supplied images without alteration.
- [6]
Alfa Laval. Automatic filters for fuel and lubricating oil. Technical information for oil filtration. Filtration theory, printed p. 9, for the relationship between flow, viscosity and pressure difference.
Read the technical reference
Checks required before a pilot
Section 2.7.1 of the reference manual includes fuel oil instructions before the lubricating oil items. Do not adopt that mixed sequence as a main oil procedure. Verify installed routing, sensor units, control action, alarms and supported disturbances. Figure 1 is conceptual; the exact ID23 tank connections remain open. No trial outcome, certification or manufacturer approval is claimed.
Sources checked on 28 October 2026.