MARITIME INNOVATION
DMS-2024A engine-room networks · Lesson 01

Auxiliary Engine High-Temperature Fresh-Water Cooling

A/E stands for Auxiliary Engine and HTFW for High-Temperature Fresh Water. Study an actual DMS-2024A-2D engine-room simulator screen step by step, connecting the diagram with heat transfer and operating indications.

Vocational learners / 17–19DMS-2024A-2D · ID 32Free learning resource

Learning outcomes

This screen concerns the three auxiliary generator engines, not the main propulsion engine. The goal is to connect a system diagram to engineering principles without mistaking a designed flow path for confirmed water circulation.

Generator set — GenSet
A diesel engine coupled to an electrical generator. The engine supplies mechanical power; the generator converts it to electrical power.
LTFW — Low-Temperature Fresh Water
Fresh water serving cooling loads at a lower temperature level. “High” and “low” are relative to the plant design.
Jacket-water passage
A water passage around hot engine parts, such as cylinder liners, through which the water exchanges heat with the metal.
  • Identify the main HTFW/LTFW components and three auxiliary engines.
  • Describe the intended water path in the correct order.
  • Explain conduction, convection and engine preheating.
  • Interpret readings without inventing measurement units or active flows.

How to study: identify components → trace the pipes → explain heat transfer → check the readings → justify your answer. Pressure alone does not establish circulation.

What the screenshot actually shows

Visible temperatures36.0 °CT 36.0
Pressure indicationP 1.6Unit not legible in screenshot
Flow indicationG 0.0At visible measurement points

The screen includes No. 1, No. 2 and No. 3 GEN. ENGINE, the G/E J.W. Heating Unit (94), LTFW connections, AIR CLR and L.O. CLR, three T.C. 85.0 controls, and the L/T Cool F.W. EXP. TK., an expansion tank that accommodates water-volume changes and allows make-up water to be supplied. Each engine has an E 0.0 indication.

⚠ Interpretation note: diagram arrows indicate intended directions; displayed G 0.0 values do not establish active flow. The units for pressure and flow need confirmation in the simulator or its manual.

Follow the network using two illustrations

Numbered educational annotation of the DMS-2024A-2D A/E HTFW network including preheater, generators, temperature controllers and LTFW connections
Figure 1. Numbered components shown on the actual simulator screen (English teaching annotation).Open full-resolution image ↗
Simplified diagram showing the HTFW preheating loop and separate LTFW heat loads such as air cooler and lubricating oil cooler
Figure 2. Simplified HTFW preheating and LTFW cooling model (English labels). Not a manufacturer P&ID (piping and instrumentation diagram).Open full-resolution image ↗
Show the original DMS screenshot
Original DMS-2024A auxiliary engine HTFW cooling screen with three generator engines and numerical readings
DMS-2024A-2D screen with the recorded operating indications; desktop taskbar omitted.Open full-resolution image ↗
One screen, several functions: although the title says HTFW, LTFW connections also appear. During preheating, water transfers heat to cooler metal; during engine operation, water receives heat from hotter metal. A common preheating header does not mean the heater runs continuously or all three engines are in the same operating state.

Tracing the water path — six steps

We follow the diagram’s intended structure. Actual active flow depends on pump status and valve positions.

Preheating unit — G/E J.W. Heating Unit (94)

The left side shows a circulation pump, which moves water around a loop, and a heating element, which supplies heat to the water. When preheating is enabled, the pump circulates water and the heater supplies thermal energy. This prepares the engine for starting and reduces sudden temperature gradients.

Common distribution and supply branches

A header is a common pipe connected to several branches. The magenta header leads toward the three auxiliary engines. Visible branch valves are WB-V21S (No. 1), WB-V20S (No. 2) and WB-V19S (No. 3). A drawn pipe does not prove that its valve is open or that water is flowing.

Flow through engine cooling passages

Fresh water circulates through the jacket-water passages and specified cooled parts. While the engine is running, water absorbs heat from the engine metal. During preheating, warmer water can instead supply heat to the cooler metal.

Upper common return header

Visible rising branches incorporating WB-V22S, WB-V23S and WB-V24S connect to the upper magenta header. Diagram arrows point left, toward the preheating area, provided this route is enabled.

Low-temperature fresh-water (LTFW) circuit

The bottom part shows LTFW connections and local branches to the air cooler (AIR CLR) and lubricating-oil cooler (L.O. CLR). LTFW serves thermal loads at a different temperature level from jacket-water cooling. The exact hydraulic routing requires verification against the DMS manual and operational indications.

Temperature control — T.C. 85.0

Each engine shows T.C. 85.0 while visible measured temperatures indicate T 36.0. A temperature controller compares temperature with a desired setting and influences flow. The former value is treated as a displayed controller setting, not a measured water temperature. This single screenshot cannot establish the precise position or internal action of the thermostatic valve.

Manual cross-check: the supplied DMS-2017A manual, §5.2, pp. 22–23, Figure 5-3, describes auxiliary-engine preheating with an electric heater and a circulation pump. Section 5.3 links LTFW to the central coolers and heat rejection to sea water. This comparison supports the general principle; it does not automatically validate DMS-2024A units, settings or valve positions.

The physics of heat transfer

During normal engine operation, heat passes through the engine metal by conduction (heat transfer through solid material) and from the metal surface to circulating fresh water by convection (heat exchange between a surface and moving fluid). During preheating the direction of heat transfer can reverse, from water to engine metal.

Thermal power is heat transferred per unit time: 1 kW is 1 kJ per second. Under steady-flow conditions, properties at each point remain approximately constant with time. The thermal power transferred to the water is then approximated by:

Q̇ = ṁ × cₚ × (Tout − Tin)

where ṁ is mass flow (kg/s), the kilograms of water passing per second; cₚ is specific heat [kJ/(kg·K)], the energy per kilogram required for a temperature rise of 1 K; and ΔT is outlet minus inlet temperature. A difference of 1 K equals a difference of 1 °C. Positive ΔT means the water gains heat.

Worked example: ṁ = 2 kg/s, cₚ = 4.18 kJ/(kg·K), ΔT = 8°C. Then Q̇ = 2 × 4.18 × 8 = 66.88 kW. These are teaching values, not DMS measurements.

This approximation assumes liquid water without phase change, approximately constant specific heat, negligible kinetic and potential energy changes, steady flow and negligible mechanical work across the chosen section. The value cₚ = 4.18 is illustrative; the actual value depends on conditions.

Try the calculation

Result: 66.88 kW for the example values.

Six questions with answers

Open each question to check the explanation. Suitable for classroom review or independent study.

1. What is the purpose of HTFW cooling?

It absorbs and removes heat from cooled auxiliary-engine components to maintain suitable operating temperatures. Preheating serves a different purpose: keeping the engine thermally ready for starting.

2. Why is preheating useful before starting?

It limits temperature differences and the associated thermal stresses, helping the engine remain in a suitable thermal standby condition.

3. How do HTFW and LTFW differ?

HTFW is primarily associated with higher-temperature engine parts; LTFW serves lower-temperature loads such as air and lubricating-oil coolers. The actual interconnections depend on the plant design.

4. What is the difference between T.C. 85.0 and T 36.0?

T.C. 85.0 appears as a temperature-controller setting. T 36.0 appears as a measured temperature at selected points. They are not two temperature measurements at the same point.

5. Why do arrows not prove actual water flow?

They represent designed directions. Visible G 0.0 indications do not establish active flow at those measuring points. Pump, valve and sensor indications must be considered together.

6. What should we check if cooling-water temperature rises?

Check temperature, pressure and flow readings; pump and valve status; temperature control; LTFW availability; and alarms. Follow approved procedures and instructor supervision before making any changes.

Practice on the simulator

With instructor supervision, compare two operating states: stopped and an approved operating state with one auxiliary engine running. Use the same measuring locations. Do not operate controls solely on the basis of this article.

Without a simulator: locate the preheating unit, one auxiliary engine and the two coolers. Sketch the water path separately from the direction of heat transfer. Organise your notes as “visible in the image”, “explained by theory” and “requires verification”. Then check the six answers.
ParameterStoppedOperatingObservation
HTFW temperature———
Pressure indication P———
Flow indication G———
Circulation pump status———
Valve indications / positions———
Temperature controller indications———

Discussion: Which indication confirms flow? In which direction is heat transferred during running and preheating?

Teaching pack, sources and limits

Download the full English-language Word lesson with diagrams, technical explanations, answers and a simulator observation sheet. This educational article does not replace vessel procedures or approved manufacturer manuals.

Download Word (English)

Sources

  1. Original «A/E HTFW Cooling System» screen, DMS-2024A-2D, ID 32 (provided for this lesson).
  2. English numbered teaching annotation and original English learning schematic based on the supplied screenshot.
  3. General heat-transfer and engine-cooling principles; unverified valve positions or units are not guessed.
  4. DMS-2017A Engine-Room Simulator Manual, §5.2–5.3, pp. 22–24, Figures 5-3 and 5-4. Supplied for technical cross-checking; this is a different version from the DMS-2024A screenshot.
  5. U.S. Department of Energy — DOE-HDBK-1012/2-92, Heat Transfer: conduction, convection and energy balances. General theoretical support, not a DMS operating procedure.

Related technical studies: LTFW cooling and main-engine HTFW cooling. Return to Simulator lessons for the growing collection.

Auxiliary EnginesHTFWLTFWDMS-2024AJacket WaterHeat Transfer